Aids to Navigation monitoring data

Parameter Number of bits Description
Message ID 6 Identifier for this message 6; always 6.
Repeat Indicator 2 Used by the repeater to indicate how many times a message has been repeated.

0 – 3; default = 0; 3 = do not repeat any more.

Source ID 30 MMSI number of source Unit
Sequence Number 2 0 – 3
Destination ID 30 MMSI number of destination Unit.
Retransmit Flag 1 Retransmit Flag should be set upon retransmission:

0 = no retransmission = default

1 = retransmitted.

Spare 1 Not used.  Should be zero.
DAC 10 Destination Area Code.

Default: 235 (UK & NI) or 250 (ROI)

FI 6 Function Identifier

Default: 10 for this GLA standard message

Analogue (internal) 10 0.05- 36V 0.05V step Supply voltage to AIS Unit

0 – Not Used

Analogue (external –

from hardware analogue input No 1

10 0.05 – 36V 0.05V step

0 – Not Used

Analogue (external –

from hardware analogue input No 2

10 0.05 – 36V 0.05V step

0 – Not Used

Status Bits   0 / 1

(internal – same as the 5 LSBs of status bits from Message type 21)

5 4  \ /  00 – no RACON installed;  01 – RACON not monitored

3  / \  10 – RACON operational;  11 – RACON ERROR

2  \ /  00 – no light or no monitoring;  01 – Light ON

1  / \  10 – Light OFF;  11 – Light ERROR

0    0 – Good Health, 1 – Alarm

Status Bits   0 / 1

(external – derived from hardware digital inputs)

8 7  Digital Input   Off/ / On

:

:

0  Digital Input   Off/ / On

Off Position Status 1 Off position or On position

0:  On position

1:  Off position

Spare 4 For future use.  Should be zero.
TOTAL OF BITS. 136 Occupies 1 slot.
IALA WWA Academy
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

IALA complies with the General Data Protection Regulations of the EU. IALA will include a list of participants with their contact information on the website and in the report of this meeting. Any participant who wishes to remove their contact details from the participants' list should advise the Committee Secretary as soon as possible.