Standard Message Header |
Message ID |
6 |
Identifier for Message 8; always 8. |
Repeat Indicator |
2 |
Used by the repeater to indicate how many times a message has been repeated. (See ITU-R M.1371-3, Annex 2, § 4.6.1).0 – 3; 0 = default; 3 = do not repeat any more. Set to 0 (default). |
Source MMSI |
30 |
MMSI number of source station. This varies according to the transmitter ID. |
Spare |
2 |
Not used. Set to zero |
Binary Data |
Designated Area Code |
10 |
Designated area code (DAC). (See Rec. ITU-R M.1371-3 § 2.1, Annex 5). Set to 366 (US). |
Function Identifier |
6 |
Function identifier. Set to 22 |
Application Data |
Message Linkage ID |
10 |
A source specific running number, unique across all binary messages equipped with Message Linkage ID. Used to link additional information to the message by a Text Description message. The Message Linkage ID and the first six digits of the source MMSI uniquely identify the sent message. 1 – 1,023; 0 = not available = default. |
Notice Description |
7 |
Notice Description as per Table 11.
Set to 0 – 127 according to description. If 127, there must be associated text (see Table 10). |
Start time of Area |
UTC month |
4 |
UTC month of the Area start. 1 – 12; 0 = UTC month not available = default; 13 – 15 (reserved for future use). |
UTC day |
5 |
UTC day of the Area start.1 – 31; 0 = UTC day not available = default. |
UTC hour |
5 |
UTC hour of the Area start. 0 – 23; 24 = UTC hour not available = default; 25 – 31 (reserved for future use). |
UTC minute |
6 |
UTC minute of the Area start.0 – 59; 60 = UTC minute not available = default; 61 – 63 (reserved for future use.) |
Duration |
18 |
Minutes until end of Area Notice, measured from start time of Area Notice. Maximum duration is 262,142 minutes (182.04 days).0 = cancel Area Notice; 1 – 262,142; 262,143 = undefined = default. |
Sub-area 1 |
90 |
Area description, structured as in
Table 5 – Table 10. A short text description may be associated with the areas using Sub-area 5: Associated text. 2-slot message. |
Sub-area 2 |
90 |
Optional additional area, structured as in
Table 5 – Table 10. 2-slot message. |
Sub-area 3 |
90 |
Optional additional area, structured as in
Table 5 – Table 10. 3-slot message. |
Sub-area 4 |
90 |
Optional additional area, structured as in
Table 5 – Table 10. 3-slot message. |
Sub-area 5 |
90 |
Optional additional area, structured as in
Table 5 – Table 10. 3-slot message. |
Sub-area 6 |
90 |
Optional additional area, structured as in
Table 5 – Table 10. 4-slot message. |
Sub-area 7 |
90 |
Optional additional area, structured as in
Table 5 – Table 10. 4-slot message. |
Sub-area 8 |
90 |
Optional additional area, structured as in
Table 5 – Table 10. 5-slot message. |
Sub-area 9 |
90 |
Optional additional area, structured as in
Table 5 – Table 10. 5-slot message. |
Sub-area 10 |
90 |
Optional additional area, structured as in
Table 5 – Table 10. 5-slot message. |
Spare |
1-7 |
From 1 to 7 spare bits, added to make the total message length an even number of bytes. Set all spare bits to 0. |
Total |
208 – 1016 |
2-5 slot message |