Capability reply

Introduction/Additional information:

This IFM should be used by a ship or a base station to reply to a capability interrogation message.
The reply contains a table of the implemented application identifiers.

This IFM should be returned to the interrogating station only.

Registrant:
ITU-R.M.1371-1
Message number:
6
DAC:
1
FI:
4
State:
in force
Number of slots (max):
1
Permitted as from:
01/01/1998
Details:
 Parameter Number of bits  Description
 IAI/DAC code 10  See Annex 2, Table 20
 Capability mask 128  IAI/DAC FI capability table, two consecutive bits should be used for every IAI/DAC FI as follows: first bit: IAI/DAC FI available if set to 1  IAI/DAC FI not available if set to 0 =default  second bit: reserved for future use, such as version indication  should be set to zero
 Spare 6  Spare. Should be set to zero
 Total number of bits   80

Annex 2, Table 20

 DAC  Function identifier  Resulting application identifier (binary)  Resulting application identifier (hex)  Description
1 0  0000 0000 0100 0000 40  Use of these messages, e.g. for aids-to-navigation, VTS, search and rescue, should be as defined in Annex 5
1 1  0000 0000 0100 0001 41
1 2  0000 0000 0100 0010 42
1 3  0000 0000 0100 0011 43
1  …  0000 0000 01XX XXXX  …
1 63  0000 0000 0111 1111  007F
IALA WWA Academy
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

IALA complies with the General Data Protection Regulations of the EU. IALA will include a list of participants with their contact information on the website and in the report of this meeting. Any participant who wishes to remove their contact details from the participants' list should advise the Committee Secretary as soon as possible.